Features
- -82 to 82 ft/s (-25 to 25 m/s)
- ±0.25% of reading above 1.6ft/s (0.5m/s)
- ±1.25 mm/s of reading below 1.6ft/s (0.5m/s)
- ±0.15% repeatability
- -40 to 140°F (-40 to 60°C) operating temperature
- Fluid temperature depends on electronics mounting
- -40 to 185°F (-40 to 85°C) for local mount
- -40 to 302°F (-40 to 150°C) for remote mount
- Built-in magnetic, six-button, lockable keypad
The Panametrics PanaFlow Z3 ultrasonic flow meter does not require maintenance since it does not have any obstruction in the flow path that could clog the line, nor does it have any moving parts that could be damaged by the flowing fluid. The PanaFlow Z3's measurement is not affected by changing process conditions (temperature, pressure, and conductivity) and does not drift over time that would require periodic calibration.
Panametrics PanaFlow Z3 Ultrasonic Flow Meter Applications
Process control and monitoring
Allocation measurement
Batching blending files
Transfer lines
Cooling water lines